Wednesday, September 2, 2015

Specifications Total Station for Topcon GTS 255

 

  Highlights

  • Single prism measurement up to 7,454'
  • 24,000-point internal memory
  • Accuracy up to 5 seconds
  • Pre-installed surveyor software
  • Easy to read LCD display 
  • Specifications for the Topcon GTS 255 5 Second Total Station

    General
    Weight10.8 lbs (4.9 kg)
    Dimensions7.2 in x 6.8 in x 13.2 in (18.4 cm x 17.2 cm x 33.6 cm)
    Protection ClassIP54 (protected against dust and water splashes)
    Internal Memory24,000 points
     
    Angle Measurement
    Measuring Method/Reading SystemAbsolute encoder
    Detection MethodHorizontal: double, Vertical:single
    Minimum Reading1-second/5-second
    Accuracy5-Second
    Diameter of Circle71 mm
     
    Distance Measurement
    Unit of Measure (distance display)m/ft
    EDM Accuracy (Precision) ±(2mm + 2ppm x D)
    Minimum Reading 900 m (3,000 ft)
     
    Tilt Sensor/Compensator
    Range± 3
    TypeAutomatic vertical and horizontal
    MethodLiquid surface reflective profile sensor reading
    Setting Accuracy1 arcsec
     
    Battery/Power
    Power SourceRechargeable Ni-MH battery
    Battery Life9 hours
    Battery Life Alert yes
    Voltage7.2V
     
    Optical Plummet
    ImageErect
    Magnification3x
    Field of View5 degrees
    Focus Range0.5 m to infinity
     
    Level
    Plate/Tubular Bubble Vial30 seconds per division/(2 mm)
    Circular Bubble Vial 10 minutes per division/(2 mm)
     
    Telescope
    Length of Tube150 mm
    ImageErect
    Diameter of Objective Lens (Aperture)1.77 in (45mm) EDM: 1.97 in (50 mm)
    Magnification30x
    Field of View1 degree 30 arcmin
    Resolving Power3.0 arcsec
    Minimum Focus Distance1.3 m (4.2 ft)
    Reticle IlluminationProvided
     
    Display and Keypad
    Type2 screen, dot matrix graphic LCD display
    KeysAlphanumeric
    Backlightyes
     
    Temperature
    Operating-4Fº~122ºF (-20ºC~50ºC)
     
    Applications
    Surveying and Constructionyes
    Mapping and GIS (geographic information systems)yes
    Utilitiesyes
    Environment Studiesyes
    Geomarkingyes
    Archaeology yes
    Accident Reconstructionyes
     
    Measurement Range (under fair weather conditions)
    Single Prism7,545 ft. (2,300 m)
    Triple Prism10,200 ft. (3,100 m)
    Mini Prism3,000 ft. (900 m)
     
    Functions
    Coordinate Measurement Pointyes
    Angle and Distance Stake Out yes
    Stake Out Lineyes
    Offsetsyes
    Missing Lineyes
    Remote Elevationyes
    Resectionyes
    Area Calculationyes
     
    Measurement Time
    Fine1 mm: 1.2 seconds (Initial 4 seconds); 0.2 mm: 2.8 seconds (Initial 5 seconds)
    Tracking0.4 seconds (Initial 3 seconds)
     
    Interface
    Pin Port9-pin (RS-232C) See All...
     

No comments: